Skip to main content

Table 2 Comparison of mean reduction in microbial load between the aluminium milk handling cans (Control) and plastic milk handling jerry cans

From: Effectiveness of the sanitation regimes used by dairy actors to control microbial contamination of plastic jerry cans’ surfaces

Type of the equipment

N

Type of microorganism (mean log10 cfu/cm2)

Initial microbial load

Final microbial load

Change in microbial load

% Microbial load reduction

Aluminium

12

TVC

5.86 ± 0.92

0.82 ± 0.34

5.06 ± 0.88

86.3

12

TCC

4.53 ± 1.17

0.70 ± 0.25

3.83 ± 1.02

84.5

12

LAB

3.77 ± 0.74

0.13 ± 0.08

3.60 ± 0.77

95.5

Plastic

48

TVC

5.99 ± 1.03

3.84 ± 0.92

2.50 ± 0.66

35.9

48

TCC

5.07 ± 0.91

3.64 ± 0.80

1.43 ± 0.68

28.2

48

LAB

4.81 ± 0.81

2.75 ± 1.07

2.03 ± 0.87

42.2

  1. Key: TVC total viable count, TCC total coliform count and LAB lactic acid bacteria